Lancaster farming. (Lancaster, Pa., etc.) 1955-current, June 04, 1977, Image 123

Below is the OCR text representation for this newspapers page. It is also available as plain text as well as XML.

    f nn *■» k
June
explanation of the revolutionary
new MUELLER “FRE-HEATER™”
FOR THE DAIRY FARM
Bulk milk coolers on modern dairy farms remove heat from
the milk promptly after it is produced. To accomplish this
requires refrigeration machines and they are generally of
the air-cooled type. Air-cooled condensing units literally
“throw away’’ this valuable heat.
On these same farms, large amounts of hot water are need
ed for "prepping" the cows, washing the milk cooler, the
pipeline milker, other equipment, and the milking parlor
itself. It is also advantageous to heat the cows’ drinking
water in winter.
The Mueller Fre-Heeter conserves energy and provides
"free” hot water by capturing the heat now wasted!
HERE’S HOW IT WORKS:
Rather than using noisy, dust-creatmg fans with fragile,
dirt collecting air-cooled condensers, the refrigerant is
routed to a specially designed condenser/heat exchanger
and its heat is transferred to the water
A thermostatically controlled valve delivers 145° F water
to the storage tank.
In addition to the thermostatic valve, a mixing valve is pro
vided to permit “prepping” temperature water.
Thus, the Fre-Heater delivers two temperatures c f water
prepping and washing.
Tests indicate the Fre-Heater consumes 10% less power
than an air-cooled-system ... and you gel Free Hot Water!
ELIMINATES REFRIGERATION SERVICE PROBLEMS!
The most common causes of slow cooling in bulk milk
cooling systems are related to the air-cooled condenser.
Three things which frequently reduce the efficiency are;
1 Poor, air circulation and recirculation
2 Fan motor failures
3 Dirty or clogged condenser fins
Air-cooled condensing units are generally installed out of
doors in order to assure adequate air supply to the con
denser. This exposes the compressor to extreme ambient
temperatures. Starting problems and compressor failures
have resulted and air-cooled condenser units are always
noisy.
The Fre-Heater eliminate* these, prpblemsbecsuse:
* There is no air-coofed J fcdndenser.
* The Fre-Heater is installed indoors,
* There are no fanh to generate? noise.
* The head pressure is very stable assuring longer
compressor life. '
* There are £Q cold weather starting problems, plus
... the Fre-Heater conserves energy and produces
Free Hot Water!
MAKE ME A BULK MILK
COOLER THAT HAS
CONTACT QUEEN ROAD REPAIR 10 SEE A
QUEEN ROAD REPAIR
BOX 67, INTERCOURSE, PA 17534
After 5 P.M.
_J_OHN D. WEAVER 656-9982
GID DIENNER 768-8521 SAM STOLTZFUS 768-3594
OR Answering Service 354-4374 24 Hour Service
' We Stock Hess’ Farm Supplies, Check Our Prices on Animal Medications
DAIRY MONTH...
IS
SPECIAL TANK PRICES THRU JUNE 30TH
Save
Energy
and get
HOT
WATER...
with the
revolutionary...
-> DAIRY MONTH SPECIAK
MEW TANKS
400 Gal. Mueller
MHL
500 Gal. Mueller M
500 Gal. Mueller
MHL
600 Gal. Mueller M
I MUEL.L.EP
1 I
FRg HBATSR"
FRB-HBATBR™
THE ALL STAINLESS STEEL
MODEL-C FRE-HEATER FOR ALL BULK TANKS
See Fre-Heater Story on page 106
IN OPERATION, RIGHT ON THE FARM.
(2) 425 Gal. Esco
C-200 Gal. OeLaval
300 Gal. Mojonnier
300 Gal. Sunset
300 Gal. Jamesway
300 Gal. Zero
PHONE 717-768-7111
\ \ I J Cf I I » r-K**.• " *.««( i . _ r
Lancaster Farming, Saturday, June 4.1977—12:
THE "MW” 1$ ONE OF THE LOWEST
POURING HEIGHT BULK TANKS.
CHECK WITH US ABOUT ALL THE
ADDED NEW FEATURES OF THE
"MW” BULK TANK.
FRE-HEATER SYSTEM
WORKS ON MUELLER
NEW MODEL "MW”
USED TANKS
350 Gal. Esco
500 Gal. Dari-Kool
400 Gal. Mojonnier
425 Gal. Esco
400 Gal. Dari-Kool
600 Gal. Girton
: MILKING EQUIPMENT :
!•••••••••••••••
18 can Can Cooler
600 Gal. Milkeeper
Tank
800 Gal. Mojonnier
650 Gal. Esco
500 Gal. Mueller ME
USED TANKS
AND
IN STOCK
!3